Polarity Reversing Pulse Plating Rectifiers

Sol Rectifiers PHFSPD PR P

Programmable High Frequency Switching Power Devices

Description

Our polarity reversing pulse plating rectifiers are reasonably priced, provided with 4 wave form output as standard features suitable for the most demanding electroplating requirements:

Anodizing
Brush plating
Electrocoagulation
Electrodegreasing
Electroetching
Electroforming
Electrophoresis
Electroplating
Electropolishing
Electrowinning

Intuitive LCD Interface

plating rectifier interface, electroplating rectifier interface, programmable plating rectifier interface, programmable electroplating rectifier interface

Technology

IGBT programmable high frequency switching power device

DC Smoothed Wave Output

Low ripple smoothed wave polarity reversing pulse plating rectifiers suitable for the most stringent electroplating requirements including single metal, complex multi metal, decorative and hard chrome depositions

Standard Features

CONST – Constant smoothed wave output
HL P – High low pulse wave output
PR P – Polarity reversing pulse wave output
SW – Sine wave output

PLC communication port RTU RS485

Optional Features

PLC analog signal communication port N/A

Other Available Rectifier Models

Compact Bench Top Polarity Reversing Pulse Plating Rectifiers

plating rectifier, electroplating rectifier, programmable plating rectifier, programmable electroplating rectifier
Volt Output Range

Standard unit 0~12 V
Other output on request

Ampere Output Range
30 A, 50 A, 100 A, 150 A, 200 A

Remote Control Bench Top Polarity Reversing Pulse Plating Rectifiers

plating rectifier controller, electroplating rectifier controller, programmable plating rectifier controller, programmable electroplating rectifier controller
plating rectifier, electroplating rectifier, programmable plating rectifier, programmable electroplating rectifier
Volt Output Range

Standard unit 0~12 V
Other output on request

Ampere Output Range
30 A, 50 A, 100 A, 150 A, 200 A

CONST – Constant Smoothed Wave Output

plating rectifier interface, electroplating rectifier interface, programmable plating rectifier interface, programmable electroplating rectifier interface
Pre-Settable Parameters

Mode CV or CC
Output V or A
Timer for soft start
Timer for soft stop
Timer for auto cut-off

CV/CC
0 to unit rated output
0 to 9999 S
0 to 9999 S
0 to 9999 S/M/H

PR P – Polarity Reversing Pulse Wave Output

plating rectifier interface, electroplating rectifier interface, programmable plating rectifier interface, programmable electroplating rectifier interface
Pre-Settable Parameters

Mode CV or CC
Forward output V or A
Reverse output V or A
Timer for soft start
Timer for soft stop
Timer for forward pulse on
Timer for forward pulse off
Timer for reverse pulse on
Timer for reverse pulse off
Sum for forward pulse repetition
Sum for reverse pulse repetition
Timer for auto cut-off

CV/CC
0 to unit rated output
0 to unit rated output
0 to 9999 S
0 to 9999 S
*1.0 to 999.9 mS
*1.0 to 999.9 mS
*1.0 to 999.9 mS
*1.0 to 999.9 mS
1 to 9999

1 to 9999
0 to 9999 S/M/H

*Minimum increases with higher output units
12 V 3 – 100 A 1.0 to 999.9 mS, 12 V 150 – 300 A 2.0 to 999.9 mS, 12 V 500 A 5.0 to 999.9 mS, 12 V 600 – 1000 A 8.0 to 999.9 mS

HL P – High Low Pulse Wave Output

plating rectifier interface, electroplating rectifier interface, programmable plating rectifier interface, programmable electroplating rectifier interface
Pre-Settable Parameters

Mode CV or CC
High output V or A
Low output V or A
Timer for soft start
Timer for soft stop
Timer for pulse on
Timer for pulse off
Timer for auto cut-off

CV/CC
0 to unit rated output
0 to unit rated output
0 to 9999 S
0 to 9999 S
*1.0 to 999.9 mS
*1.0 to 999.9 mS
0 to 9999 S/M/H

*Minimum increases with higher output units
12 V 3 – 100 A 1.0 to 999.9 mS, 12 V 150 – 300 A 2.0 to 999.9 mS, 12 V 500 A 5.0 to 999.9 mS, 12 V 600 – 1000 A 8.0 to 999.9 mS

SW – Sine Wave Output

plating rectifier interface, electroplating rectifier interface, programmable plating rectifier interface, programmable electroplating rectifier interface
Pre-Settable Parameters

Mode CV or CC
Upper output V or A
Lower output V or A
Timer for soft start
Timer for soft stop
Timer for half wave
Timer for auto cut-off

CV/CC
0 to unit rated output
0 to unit rated output
0 to 9999 S
0 to 9999 S
*5 to 150 Hz
0 to 9999 S/M/H

*Unit will display conversion of Hz to time in mS.

Simple Operation

Sol Rectifiers PHFSPD PR P

These are programmable closed loop self-regulating units, which output can be set from 0 V to unit rated V output or from 0 A to unit rated A output.

With the intuitive LCD interface control panel, operator can easily navigate through the pre-sets requirements for each wave output.

The moment operator presses the Start key the unit will automatically maintain the pre-set output value no matter any fluctuations in the plating cell resistance or in the main electrical supply to the unit for absolute plating consistency and precise control.

Durability & Care Free Operation

Relying on our state of the art electronic protection circuitry, our units are known to operate trouble free for years on and into decades.

When units are placed in a clean fresh air environment, care free operation can be expected. Only minimal air fan cleaning may be required once or twice a year.

Order Quantity & Shipping Options

Single order unit are welcomed.

We ship straight from the factory to any parts of the world.

Depending on order weight or volume the following shipping services are available:

Speed courier
Air freight
Air freight door-to-door
Sea freight
Sea freight door-to-door

Worldwide Customers

We have a large number of satisfied customers using on a daily basis our plating rectifiers in various countries, to name a few:

Australia, Austria, China, Denmark, Indonesia, Malaysia, Philippines, New Zealand, Singapore, South Africa, Thailand, United Kingdom of Great Britain, United State of America, Vietnam, etc.

Specifications